Data unit component input selection
DU_TR0_SEL | Data unit input signal ‘tr0_in’ source selection: ‘0’: Constant ‘0’. ‘1’: Constant ‘1’. ‘2’: Data unit output. ‘10-3’: LUT 7 - 0 outputs. Otherwise: Undefined. |
DU_TR1_SEL | Data unit input signal ‘tr1_in’ source selection. Encoding is the same as for DU_TR0_SEL. |
DU_TR2_SEL | Data unit input signal ‘tr2_in’ source selection. Encoding is the same as for DU_TR0_SEL. |
DU_DATA0_SEL | Data unit input data ‘data0_in’ source selection: ‘0’: Constant ‘0’. ‘1’: chip_data[7:0]. ‘2’: io_data_in[7:0]. ‘3’: DATA.DATA MMIO register field. |
DU_DATA1_SEL | Data unit input data ‘data1_in’ source selection. Encoding is the same as for DU_DATA0_SEL. |